Vadodara
08048034185
+917817095566

Products

6814772a5d263414004dd4a4 Card 2

product image
1010kVA - 1250kVA Genset

ENGINE : Engine with lowest fuel consumption Dry type air cleaner with service indicator with lube oil & coolant Electrical starter motor with check for highest voltage capacity With battery charging alternator ALTERNATOR : Brushless, screen protected, drip proof, self-excited, self regulated IS/IEC60034-1 Reliable long life with superior class “H” insulation Highest motor starting capability Light & compact, best transient response Easy maintenance with integrated components and outdoor exciter/rotating rectifier Sealed bearing for less maintenance CONTROLLER KEY FEATURES : 4-line back-lit LCD display PIN-protected front panel editing Customisable screens with power saving mode 9 inputs & 8 outputs (configurable) 3 maintenance & alternator failure alarms Manual speed control Power & load monitoring, Earth fault trip USB, RS232/RS485, SCADA & SMS control Static battery charger for battery health KEY BENEFITS : Clear 132x64 pixel display Date & time schedulers Configurable maintenance periods Ethernet-based remote monitoring (via DSE855) BMS integration support PLC editor for custom functions CONTROL PANEL : Weather-proof and long-lasting finish Power cable/bus bars with suitable capacity Incoming/outgoing terminals Indicator lamps for Load ON & Set Running Battery charger 24V Fuses/MCBs for control circuit safety ACB of suitable rating with short circuit protection REMOTE MONITORING SYSTEM : RMS is standard scope IOT incorporated for continuous remote monitoring of engine operational parameters like running hours, health, RPM, logs of errors, and operational parameters via app and web platform. Monitor generator or entire fleet from anywhere Ensures good health and efficiency Smart Generator Management Solutions : Reduce timely notifications for maintenance Check each fueling event (Check/B Check) Tailor preventive maintenance schedules Examine fuel consumption patterns Automate maintenance tasks Boost operational transparency Fuel traceability system for accurate tracking OPTIONAL ACCESSORIES : Cold Starting System PMG Alternator Space heater RTD/BTD Auto Mains Failure/Auto Transfer Switch/Sync Controller/Sync Panel

6814772a5d263414004dd4a4 Card 2

product image
Twin DG Set 250kVA & 320kVA

Mahindra Powerol’s ‘Spectro’ series of diesel gensets is one of the most silent gensets manufactured by the brand. It has sturdy wheels and a long handle which allows easy mobility of the genset.

6814772a5d263414004dd4a4 Card 2

product image
125 kVA Gas Powered Genset

Year 2002, Mahindra and Mahindra entered the field of power generation through its engines under the brand name Mahindra Powerol. The same engines are today powering Diesel Generating Sets ranging from 5kVA to 1250kVA. Mahindra Powerol is also widely acclaimed for its fuel efficiency and quick customer response. It’s a name trusted by leading players in industries. Within a short span of time, Mahindra Powerol has garnered immense customer trust which shows its level of commitment and customer centric approach. Presently, more than 600,000 Powerol gensets are powering different industries and applications in Indian and overseas markets. Mahindra Powerol, through its technology & service has taken giant strides in the engine and genset industry. In a little over a decade, it has also expanded its footprint to South East Asia, Far East, Middle East, Africa and Europe. India’s Leading Gas Powered Genset Mahindra, with its core engineering strengths and its commitment to contributing towards cleaner environment, has led India in developing gas powered genset compliant to CPCB IV+ Norms. Components: Zero Pressure Regulator Fuel Control Valve Gas Air Mixer High Tension Ignition Coil USP: Compact and light weight Gas Genset. Lowest emissions and good reliability due to precision control electronic management system of Engine and Genset. Lower Fuel (Gas) consumption due to Dual -Diaphragm mixer Technology. Quick start enabled Genset due to fuel (Gas) high energy coil feature. Real time updates on run hours, maintenance status to customer due to IOT feature. Lowest Noise Engine / Genset due to gas operations. Best in class service network & support. FEATURES Power That Matches Your Need: Mahindra Powerol Gas Gensets are designed for continuous operation or emergency backup. Continuous models can take an additional 10% load for short durations. Built-in Diagnostics for Better Uptime: Access real-time data on mobile/desktop. Get SMS alerts and service notifications during breakdowns. Remote Monitoring Made Easy: Access real-time data on mobile/desktop. Get SMS alerts and service notifications during breakdowns. Efficient Alternator Design: Compact, rugged alternators with Digital AVR for precise voltage and quick response. Space-Saving Design: Advanced CPCB IV+ tech in a compact footprint, ideal for space-constrained setups. Durability You Can Trust: CPCB IV+ compliant, low-maintenance gensets built for long life and reliability. CONTROLLER The GC111X is a modern AMF genset controller with a user-friendly interface and full graphic LCD display (back-lit with power save mode). It supports Auto (AMF, remote start/stop, cyclic) and Manual modes. Measures voltage and frequency (1ph/3ph) for mains and genset Measures load current and power factor (true RMS)

6814772a5d263414004dd4a4 Card 2

product image
10 kVA - 650 kVA

Engine : Lowest fuel consumption Dry type air cleaner with service indicator, lube oil & coolant Engine with Electrical Starter Motor Engine with Battery Charging Alternator Acoustic Enclosure : Designed to meet stringent MoEF / CPCB norms Designed to operate in extreme climatic conditions in temperatures ranging from -10°C to 55°C without any external aid Long-lasting superlative fade-resistant paint Draw-out type fuel tank for easy maintenance Fire retardant acoustic and insulation material (PU Foam / Rockwool) for better safety Easy access for serviceable parts Pre-treatment process with UV-resistant powder coating on all parts Engine and alternator mounted on a common base frame with AVM pads Alternator : Brushless, screen-protected, drip-proof, self-excited, self-regulated as per IS/IEC 60034-1 Reliable long life with superior Class “H” insulation Easy maintenance with integrated components and outboard exciter/rotating rectifier Sealed bearings for reduced maintenance and longer service life Controller (10 kVA – 320 kVA) : GC114 with full graphic LCD display (backlit with power-save mode) Supports Auto (AMF, remote start/stop, cyclic) and Manual modes Measures voltage and frequency (1-phase / 3-phase) for mains and genset Auto Exercise Mode (2 events) for preset start/stop Monitors engine safety parameters via analog resistive sensors and digital inputs Includes totalizers (starts, hours, kWh, kVAh), event log (100 entries with RTC) Parameter configuration via PC or control keys Multi-level password protection prevents tampering Controller (DSE – 400 kVA – 650 kVA) : Key Features 4-line back-lit LCD display 9 configurable inputs & 8 configurable outputs 3 maintenance & alternator failure alarms Manual speed control (CAN engines) USB, RS232/RS485, SCADA & SMS control Static battery charger for battery health Key Benefits : Configurable maintenance periods Ethernet-based remote monitoring (via DSE855) BMS integration support PLC editor for custom functions Control Panel : Powder-coated control panel with weather-proof and long-lasting finish. The control panel consists of: Power cables/bus bars with suitable capacity including outgoing terminals Indicator lamps for “Load On” and “Set Running” Battery Charger 1 x 12 / 24 Volts DC Fuses/MCBs for control circuit safety protection MCCB of suitable rating with short-circuit protection Optional Accessories : Cold Starting System PMG Alternator, Space Heater, RTD/BTD Auto Manual Fail / Auto Transfer Switch / Sync Panel (RMS from 10 kVA onwards) Remote Monitoring System : RMS standard scope above 75 kVA with continuous remote monitoring of engine parameters such as running hours, health, RPM, and operational logs via app & web-based platform Enables monitoring of single generator or entire fleet from anywhere, anytime Can be made available for other ranges as required Smart Generator Management Solutions : Timely notifications for maintenance checks (A-Check / B-Check) to avoid missing critical service moments Preventive maintenance scheduling tailored to your generators for enhanced efficiency and reliability Automated maintenance tasks to minimize downtime and extend equipment lifespan Track fueling events to ensure accuracy and prevent fuel theft Analyze fuel consumption patterns to identify inefficiencies and improve performance Enhance operational transparency with advanced fuel traceability and tracking system

6814772a5d263414004dd4a4 Card 2

product image
5kVA Portable Diesel Gensets

Mahindra Powerol's Spectro series of portable gensets is very convenient to use. It has sturdy wheels and a long handle which allows easy mobility of the genset. Along with being compact, it packs a powerful engine that delivers high genset power output. It is ideal for small offices, retail outlets, households, makeshift shelters, small applications at off-site infrastructure sites, and other small establishments. DG SET SPECIFICATION 5kVA Rating @ 0.8 pf : 5kVA Control Panel : AMF/MCP Size (L x W x H) (mm) : 1050 x 620 x 745 Fuel Tank Capacity (Ltrs) : 15 Weight (kg) : 210 ENGINE Engine Model : KD15-441GSI4 (Lombardini) Type : Direct Injection BHP : 8.2 RPM : 3000 Cooling : Air Cooled Aspiration : Naturally Aspirated Cylinders - Bore x Stroke (mm) : 1 - 86 x 76 & 4 Stroke Displacement (cc) : 441 Governing System : Mechanical Starting System : 12V DC, 35Ah ALTERNATOR Make : NSM Voltage (Volts) : 230 Frequency (Hz) : 50

6814772a5d263414004dd4a4 Card 2

product image
Filters Supply – Fleetguard, Donaldson & OEM Filters

We supply genuine air filters, oil filters, and fuel filters from trusted brands such as Fleetguard, Donaldson, and OEM manufacturers. Filters play a critical role in protecting engines from dust, dirt, and contaminants. Clean filters ensure proper airflow, fuel purity, and lubrication efficiency, helping engines operate smoothly and efficiently. We provide filters for diesel generators, industrial engines, and heavy equipment. Our genuine filters improve performance, reduce wear, and extend equipment life.

6814772a5d263414004dd4a4 Card 2

product image
Diesel Engine & Industrial Oil : Valvoline, Coolant, Valvoline

We supply high-quality diesel engine oils, industrial lubricants, and coolants, including trusted brands like Valvoline. Proper lubrication is essential to reduce engine wear, maintain temperature control, and improve engine efficiency. Our products help reduce friction, prevent overheating, protect engine components, and improve overall performance. We supply engine oil, coolant, hydraulic oil, and industrial lubricants suitable for DG sets and industrial engines. Regular use of quality lubricants helps extend engine life, reduce maintenance costs, and improve fuel efficiency.

6814772a5d263414004dd4a4 Card 2

product image
Alternator Repair & Rewinding – Kirloskar, Stamford, Crompton, Leroy Somer, AVK

We provide professional alternator repair and rewinding services for leading brands such as Kirloskar, Stamford, Crompton, Leroy Somer, and AVK. Alternators play a vital role in converting mechanical energy into electrical power, and proper maintenance is essential for reliable power generation. Our services include fault diagnosis, insulation testing, rotor and stator inspection, bearing replacement, and winding repair. We perform complete rewinding using high-quality copper wire and insulation materials to restore alternator efficiency. We also perform varnishing, baking, balancing, and load testing to ensure reliable operation. Our services help extend alternator life, improve efficiency, and prevent costly replacements.

6814772a5d263414004dd4a4 Card 2

product image
Parts Supply Mahindra, Greaves, Cummins, Kirloskar, Catterpillar, detroit, Komatsu, Ashok Leyland.

We supply genuine and high-quality spare parts for major diesel generator and engine brands including Mahindra, Cummins, Kirloskar, Greaves, Caterpillar, Detroit, Komatsu, and Ashok Leyland. Using genuine spare parts is essential to maintain performance, safety, and durability of generators and engines. We supply a wide range of components including engine parts, electrical components, alternator parts, sensors, controllers, fuel system parts, cooling system components, and control panel accessories. All parts supplied by us meet OEM standards and ensure proper compatibility and long service life. We help customers avoid downtime by maintaining ready stock and providing fast delivery. Our spare parts support helps industries maintain equipment reliability, improve efficiency, and reduce maintenance costs.

6814772a5d263414004dd4a4 Card 2

product image
Electrical Control Panel AMF, PLC BASE, Synchronizing & Load Distribution

We provide complete service, maintenance, and repair solutions for Electrical Control Panels, including AMF (Automatic Mains Failure), PLC-based panels, Synchronizing Panels, and Load Sharing Systems. Control panels are the brain of power and automation systems, ensuring safe and efficient operation of generators and electrical equipment. Our services include inspection, troubleshooting, repair, and preventive maintenance of control panels to ensure reliable system performance. We diagnose and repair faults related to relays, contactors, timers, PLC modules, SMPS units, protection circuits, wiring faults, and communication systems. AMF panels are critical for automatic DG set operation during power failures. We ensure proper sensing, automatic start/stop functions, and load transfer performance. PLC-based panels are checked for program faults, I/O module failures, communication errors, and controller malfunction. Synchronizing panels ensure safe parallel operation of multiple generators. We service synchronization relays, controllers, voltage regulators, and load sharing modules to maintain stable voltage, frequency, and load balance. Our services also include panel cleaning, tightening of electrical connections, calibration, software troubleshooting, and functional testing under load conditions. We help industries improve power reliability, prevent system failures, and ensure safe operation of their electrical infrastructure.

6814772a5d263414004dd4a4 Card 2

product image
Annual Maintenance Contract (AMC) – Comprehensive & Non-Comprehensive for Mahindra Powerol DG Sets

We provide reliable and professional Annual Maintenance Contract (AMC) services for Mahindra Powerol Diesel Generator Sets, ensuring uninterrupted power supply and long-term equipment performance. Regular maintenance is essential for DG sets to operate efficiently, reduce unexpected breakdowns, and extend equipment lifespan. Our AMC services are designed to provide complete preventive maintenance, timely inspection, and expert technical support. We offer both Comprehensive AMC and Non-Comprehensive AMC options based on customer requirements. In a Comprehensive AMC, all preventive maintenance, routine servicing, spare parts replacement, and labor charges are covered, ensuring complete peace of mind and predictable maintenance costs. This includes replacement of filters, belts, hoses, electrical components, and other critical spare parts whenever required. In a Non-Comprehensive AMC, we provide regular inspection, servicing, cleaning, testing, and preventive maintenance, while spare parts are charged separately. This option is suitable for customers who prefer flexible maintenance while ensuring their DG sets remain in optimal condition. Our AMC services include routine inspection of engine performance, alternator health, control panel functionality, fuel system efficiency, cooling system performance, and battery condition. We also perform load testing, voltage and frequency checks, oil level inspection, coolant testing, and safety verification to ensure proper DG set operation. Our trained technicians follow manufacturer-recommended maintenance schedules and use genuine spare parts to maintain equipment reliability and efficiency. We also provide emergency breakdown support and quick response services to minimize downtime. With our Mahindra Powerol DG AMC services, customers benefit from improved generator reliability, reduced operating costs, longer equipment life, and uninterrupted power supply for industrial, commercial, and residential applications.

6814772a5d263414004dd4a4 Card 2

product image
Alternator and Motor repairs

A C Generator Rewinding with H Class Copper Wire & Insulation. Epoxy coating & varnishing , AC /Dc and variable speed Motor rewinding . ARC for Motors rewinding with mechanical jobs. On site job execution of critical motor bearing replacement & servicing.

Phone Number

08048034185

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address Plot No. 730, opp. Brahma CAD Services, Makarpura GIDC, Makarpura, Vadodara

Vadodara, India, 390010